Configure Advanced ECG Review

If CalECG is intended to be leveraged to support advanced ECG review, display and review strategies may be established on a per-study basis to provide sensible waveform defaults during the review process. The following defaults may be configured to support interaction with ECG waveforms:

  • ECG Review Strategy: Default review strategy per ECG measurement protocol (Three Consecutive Beats, Representative Beat, Super Imposed).

  • ECG Review Lead: Lead to be measured (I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6).

  • ECG Display Strategy: Default display strategy per ECG measurement protocol (Three Consecutive Beats, Representative Beat, Super Imposed).

  • ECG Display Lead: Default lead to be displayed (I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6). If no lead is specified, all leads will be displayed.

  • ECG Compute Annotations: If checked, caliper positions will attempt to default upon measuring the ECG.

Exported and Printed Copies Are Uncontrolled