© 2025 IQVIA - All Rights Reserved
Study > Lab Data Export (Report)
Goal
The Study > Lab Data page allows to export information about the Lab Results.
Filters
To generate a lab data review report, navigate to the following path: Study > Lab Data > Select the Data Filters > Search > Export.
The Lab data filters enable quick identification of data fields for review, querying, and study oversight. Filtering by Epoch (study stage) and Cohort narrows the subject population. For example, you might need to view all lab results for Cohort 1 screening. The Epoch, Cohort, and Subjects filters support this search.
More information about the filters can be found here Filtering Data (Labs) - Documentation - Confluence.
Selecting appropriate filters and clicking search displays the relevant lab results. You can generate a lab data review report by clicking the export button.
The export file can be generated as an Excel or CSV file based on user preference.
Output
The downloaded file contains a detailed summary of lab results for a specific study.
This report includes the following information:
Column | Content Description | Example |
---|---|---|
Study | Name of the Study for which the lab data is reported | Lab Data Study |
Subject | Subject ID associated with the corresponding study. | 1001 / L0001 / S0001 |
Epoch | The assigned study Epoch for the subject. | Treatment |
Cohort | The assigned study cohort for the subject. | Cohort 1 |
Study Event | The study event name that corresponds with the activity outlined in the activity plan | Day 1 |
Timepoint | The scheduled data collection time points at which the activity is expected to occur. | 08:00:00 (1) |
Barcode | The barcode details for the collected lab item and are sourced from the Specimen details under Lab orders | F33733 |
Draw Time | The time of lab data collection. | 2022-01-18T12:45:47 |
Study Lab Panel | The lab panel details for data collection and are sourced from the Specimen details under Lab orders. | BIOCHEMISTRY |
Panel Result Name | The lab result panel name is sourced from specimen details > Panel Results under Lab orders. | BIOCHEMISTRY |
Panel Status | The status of the ordered lab panel. The statuses include: Completed, partial, canceled, discontinued, error, hold, in process. rescheduled | Completed |
Panel Archived? | The archival status of the ordered lab panel | False |
Test Status | The status of the ordered lab test. The statuses include: Done, Not performed, Pending | Done |
Test Archived? | The archival status of the ordered lab test | False |
Test | The name of the test that has been ordered | Total protein |
Result | The output value of the lab test ordered | 68 |
Limits | The reference ranges for the ordered lab test. | >68 |
Alerts | The lab alerts that have been generated based on the provided reference range | High/Low |
Units | The measurement units for the ordered lab test. | g/L |
Review Date | The Date/Time when the lab test was reviewed. This information is sourced from Lab > Panels > Action > Review Audits | 2024-06-17T05:42:19 |
Reviewer | The username that performed the review of lab values. This information is sourced from Lab > Panels > Action > Review Audits | |
Significance | Significance assessment details of the reviewed lab values, include NCS (Not Clinically Significant)/CS (Clinically Significant) | NCS |
Repeat | Any repeat of lab tests ordered upon reviewing lab information. This information is sourced from Lab > Panels > Repeat (Checked) | Yes |
Review Notes | Notes provided by the reviewer upon reviewing of lab results. This information is sourced from Lab > Panels > Action > Review Audits | Lab data reviewed |
Lab Test Comments | The test level comments that have been updated by the lab user. This information is sourced from Lab > Orders > Specimen > Panel Result > Lab Test Details | Test comments |
Exported and Printed Copies Are Uncontrolled