© 2024 IQVIA - All Rights Reserved

Device Interfaces (Devices compatible with ClinSpark)

Summary

The following is a list of currently supported medical and laboratory device integrations.

Additional devices may be added per customer contracts/agreements.

This list does not include software only integrations (such as laboratory LIMS or eConsent) nor all device integrations more commonly used or exclusively used in later phase trials.

Device Integrations

For Communication, ‘Direct’ refers to a ‘local’ physical connection which could be via Serial port or USB (or even Bluetooth), etc. Passive generally refers to a systems interface which may be via API, webhooks, etc. and is therefore more likely to be network and / or internet based.

Domain

Device / Software

Manufacturer

Model

Communication

Domain

Device / Software

Manufacturer

Model

Communication

ECG

touchECG

Cardioline

touchECG

Direct

ECG

CardioSoft

GE HealthCare

GEH-ECG-1200 CAM Connect 14 acquisition modules

Direct

ECG

Mortara ELI

Baxter (Mortara)

All ELI models (requires ESCRIBE** or ELI Link)

Direct

ECG

RScribe Lite*

Baxter (Mortara)

AM12 / WAM

Direct

ECG

Surveyor*

Baxter (Mortara)

3.0
Includes Demographics Import, ECG Export, and Monitoring Report

Passive

Vital Signs

Dinamap (Auto-Inflate)

GE HealthCare

ProCare 100-400
CARESCAPE V100

Direct

Vital Signs

Microlife BP

microlife

WatchBP
WatchBP office

Direct
Passive

Vital Signs

Welch Allyn Vitals

Welch Allyn

Devices supported by SDK 3 or above that allow for data transfer over USB

Direct

Vital Signs

SunTech ABPM

SunTech Medical

Oscar 2

Direct

Devices marked with * are either ‘end-of-lifed’ (EOL’d), sunset, or are no longer supported by manufacturer. As such the needed software and hardware may be unavailable and support may be limited.

 

Device Integrations - Extras

Devices listed below may not be ready for full deployment in production settings for all customers. Such devices may be fully supported by IQVIA as a device / service outside of ClinSpark integration.

Domain

Device / Software

Manufacturer

Model

Communication

Domain

Device / Software

Manufacturer

Model

Communication

Actigraphy

Axivity

Axivity

AX

Passive

Actigraphy

Weight

Fitbit

Fitbit by Google

Fitbit Activity
Fitbit Weight

Passive

Body Composition

Seca Scale (seca analytics 125)

seca

mBCA 554

Passive

Demographics

Seca Scale (HL7)*

Seca

Seca 704 Scale
Seca 456 Wireless adapter; supported by EMR Flash 101

Direct

Demographics

Seca Scale (COM)*

Seca

Seca 763 Scale
Seca 460 RS-232 adapter

Direct

Dermatology

Konica Chroma Meter

Konica Minolta

CR-400
CR-410
DR-400

Direct

ECG

AliveCor

AliveCor

AliveCor

Passive

ECG

QT Medical PCA 500

QT Medical

PCA 500 12-lead resting ECG

Passive

ECG

CardioPerfect*

Welch Allyn

CardioPerfect

Direct

ECG

Spaulding Electrocardiograph*

Spaulding Medical

1.0

Direct

Glucose

AccuChek

Roche

AccuChek*
AccuChek Guide

Direct

Glucose

Dexcom G6

Dexcom

Dexcom G6
Dexcom G6 Pro

Direct

Lab

Sartorius Scale

Sartorius

All

Direct

Respiratory

EasyConnect

NDD

Easy on-PC

EasyOne ProLab

Direct

Vital Signs

BioBeat

BioBeat

BioBeat

Passive

Exported and Printed Copies Are Uncontrolled