This area of the documentation site will provide an overview of recent ClinSpark Agent releases that are available for use. Summary of releases from 2023 2024 are listed on this page and releases from previous years are linked below.
Agent Releases -
...
2024
Table of Contents |
---|
22.2 Hotfix 1
Release date
Build: 7
...
Summary
The following article outlines the Agent releases in 2024. This information is retained for reference purposes.
Customers are encouraged to update to the latest
...
Overview
This release addresses an issue with Dexcom device interfaces, ensuring that all data uploaded has the correct transmitter ID assigned. Changes in this build will be incorporated into later functional releases.
Fixes
[AGENT-137] - Address issue with transmitter IDs assigned to uploaded records for Dexcom devices
23.1
Release Date:
Build: 3
Overview
23.1 is the first functional Agent release of 2023. It introduces support for two new device interfaces: Axivity accelerometers and the GE HealthCare CARESCAPE VC150 vital signs monitor. Additionally, the release improves upon several existing interfaces: Seca EMR (HL7), Cardioline TouchECG, Welch Allyn Vital Signs Devices, and the NDD Easy OnPC spirometry system.
Improvements
[AGENT-109] Support for GE Healthcare CARESCAPE VC150 vital signs monitor
[AGENT-94] Support for Respiration (RR) parameters on Welch Allyn Vital Signs devices
[AGENT-121] Support the use of 'ArchiveDir' device parameter for TouchECG interface to improve management of local order files
[AGENT-140] Support for FIVC parameter on NDD Easy OnPC device interface
[AGENT-125] Support for Axivity accelerometer device integration
[AGENT-134] Support for LED flashing function for Axivity devices
[AGENT-135] Support for upload of Axivity data to ClinSpark subjects
[AGENT-136] Support for association of device/PC time with Axivity device data
[AGENT-142] Support for the inclusion of subject screening number in Axivity file naming convention
Fixes
[AGENT-126] Address issue with SECA EMR/HL7 interface regarding significant digits
22.2 Hotfix 2
Release date
Build: 8
Overview
This release addresses an ‘out of memory’ issue that was observed with the 22.2 HF1 release MSI. Customers utilizing Dexcom device interfaces are recommended to use this release instead of the HF1 build.
Fixes
[AGENT-152] - Address issue with JVM memory errors observed with 22.2 HF1 and certain computing devices
23.2
Release date
Build: 2
Overview
This release adds support for a new spirometry device interface, the NDD EasyOne Pro ® Lab . It also contains the bug fix for JVM memory errors, carried forward from the 22.2 HF2 release.
Improvements
[AGENT-156] - Support ability to maintain SQL Lite DB on local EOPL computer
[AGENT-148] - Add Support for NDD EasyOne ProLab Interface
Fixes
[AGENT-152] - Address issue with JVM memory errors observed with 22.2 HF1 and certain computing devices
22.2 Hotfix 3
Release date
Build: 109
Note: Build 109 has replaced Build 103 and Build 107. This update only included a requirement for the installation to overwrite all files during installation. Please ensure that you are currently running the most up-to-date Version 22.2.hf3.109
Overview
This release addresses additional ‘out of memory’ issues that were observed with the 22.2 release MSI. This also includes various fixes across Agent time and device interactions with ClinSpark, listed below. Customers utilizing Dexcom and Accu-Chek device interface are recommended to use this release instead of the previous HF1 and HF2 builds.
Fixes
[AGENT-147] - Address issue with calculating time on backfill records for Dexcom glucose device interfaces
[AGENT-160] - Address issue of JVM Consumption on Agent 22.2 due to DLL Connection
[AGENT-163] - Address issue in 22.2 Agent of Laptop TIMESET recognition
[AGENT-166] - Address issue of device specific forms interacting with other devices
[AGENT-168] - Migrate to an ISO standard time across both Dexcom device profiles (yyyy-MM-dd HH:mm:ss)
[AGENT-161] - Address issue where adjusting the clock on Accu-Chek devices results in duplicate data
[AGENT-165] - On site upload, ensure temp tokens can never be used for poller patient workflow
[AGENT-175] - Prevent misleading blinding based on Blinding Set
22.1.2
Release date
Build: 2
Overview
This release addresses an issue where a customer seeing the Technician ID in Surveyor may not be the same as the Technician ID within ClinSpark. .
Fixes
[AGENT-167] - Address issue with Technician IDs not matching within Surveyor and ClinSpark
...
Agent release.
23.3
Release date
Build: 247
Overview
This release is our first functional release that includes all formal technical documentation which is included in the Technical File listed here: ClinSpark Agent 23.3 Technical File. A bulk of this work was created in 2023 but is the first functional release of 2023. This release includes a re-organization of the codebase, various Agent application/user interface improvements, as well as improvements for Microlife Vitals and NDD EasyOne devices. Further we have added the SunTech Oscar 2 ABPM to our integrated devices.
Improvements
Issue key | Summary |
AGENT-71 | Initial Release for SunTech Medical Ambulatory Blood Pressure Monitoring (ABPM) device |
AGENT-104 | Improve the log file output and user visible error messaging associated with Microlife device interface |
AGENT-117 | Update Copyright Information and references of Foundry Health to IQVIA |
AGENT-128 | Support the included installation of Visual C++ runtime 2013 libraries via Agent MSI package |
AGENT-153 | First Contact Date Update for EOPL and EOC |
AGENT-182 | EOC / EOPL - Improve ability of Agent to recover data when site loses internet connectivity |
AGENT-183 | Make Main Agent Build include all past versions |
AGENT-191 | Update Build and Version numbering Nomenclature and include in About window |
AGENT-196 | Enable support for ClinSpark Agent downgrades |
Previous Releases
...